<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-12 18-35-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 54 dBuV NOSTALGI
Pilot RDS Phase Difference
6.2 kHz 4.2 kHz 79 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 71 kHz 19090 0,1781
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,2 dBr 5,87 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Sonja Lumme - Elakoon elama "
AF EON
89.7, 90.9, 92.7, 94.3, 98.4, 99.5 MHz -
FM Scope Max at: 71 kHz MIN: 10 kHz % above 76 kHz: 0,1781 Acquired: 2025/12/12 18.34.10 Total samples: 19090 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 4,2 dBr AVE: 5,87 dBr % above 12,2 dBr: 0,0 Last value: 6,4 dBr (2025/12/12 18.34.09) 18.20 18.22 18.24 18.26 18.28 18.30 18.32 18.34 0 2 4 6 Pm [dBr]